Selling Riser Bond Model 6000 – We Buy New Used Model 6000 (‘s) Top Dollar Paid!

If you’re looking to Sell Riser Bond Model 6000 Multi-Function Tester RD6000

Model 6000 Multi-Function Analyzer

By combining diagnostic and fault location capabilities in one instrument, the Model 6000 offers:

  • Multi-Meter DC volts, AC volts, Foreign Battery, and Resistance.
  • Insulation Resistance.
  • Pair Quality Tests – Loop Current, Noise Metallic, Power Influence, and Longitudinal balance.
  • Resistance Fault Locator (RFL) Offers Three Different Test Modes: 3-Wire, 4-Wire, and Kupfmuller.
  • Time Domain Reflectometer (TDR) Measures Through Loaded And Non-loaded Cable.

 

The productivity of your technicians relates directly to the satisfaction of your customers — that’s the philosophy behind the Model 6000 from Riser Bond Instruments. With its 5-in-1 — Multi-Meter, Insulation Resistance Tester, Pair Balance and Noise Measurements, Resistance Fault Locator and Riser Bond TDR testing capabilities, one connection lets your technicians quickly diagnose most any problem on a voice or high-speed telephone data cable. Its basic functionality makes the Model 6000 easy-to-learn; its compact size makes it even easier to use.

While five tests with one instrument is impressive, we know you demand more and the Model 6000 delivers. Selected test capabilities can be integrated — viewing RFL and TDR on-screen simultaneously allows the technician an additional means of verifying the locations of the fault. All on-screen tests are displayed using a logical “left to right” approach (with on-screen instructions) that reduces training time while increasing ease-of-use. Its compact size, carrying case and lighter weight allow for the easy transport of one instrument into remote locations or small spaces.

Display: Larger than industry standard, the Model 6000’s screen uses SUPERTWIST LCD to display test results, softkey menu, instrument setting, and status. Visual representation of each test being performed aids the technician in the interpretation of results. SUPER-STORE waveform data storage stores both on-screen and off-screen information, which can be quickly downloaded and printed.

Buying, Selling, Trading Riser Bond Model 6000

General Specifications

Physical (no case or accessories):
Height ………………………….. 6.30 in. ………………………………. 160 mm
Width …………………………… 9.45 in. ………………………………. 240 mm
Depth …………………………… 2.36 in. ………………………………… 60 mm
Weight ………………………….. 3 lbs. ……………………………………. 1.3 kg

Environmental
Operating Temp …………….. 0 C to 50 C ……………. 32 F to 122 F
Storage Temp …………………. -20 C to 60 C ………….. -4 F to 140 F
Humidity ………………………. 95% max. relative, non-condensing
Vibration ………………………. IEC 68-2-6
Shock (Bump) ……………….. IEC 68-2-29
Drop …………………………….. IEC 68-2-27
Moisture Rating ……………… IP 54

Power
Internal …………………………Rechargeable, 7.2V nickel metal hydride battery pack
External ………………………… 12 VAC or VDC, 1250mA power supply
Operating Time ……………… >6 hours without backlight
Display …………………………. 320 X 240 dot-matrix liquid crystal
display with CCFL backlighting

 

Time Domain Reflectometer (loaded and non-loaded cable)

Horizontal Resolution
<2000 ft ……………………….. <0.25 ft at 99.0% VOP, <0.07 ft at 30.0%
<0.07 m at 99.0% VOP, <0.02 m at 30.0%
>2000 ft ……………………….. 1 foot at any VOP
0.1 meter at any VOP
Vertical Resolution …………. 14 bits with 137 dots displayed
Vertical Sensitivity ………….. >65dB
Output Signal ………………… 2ns, 25ns, 100ns, 500ns, 1.5µs, 4.4µs
and 330 ms
Output Balance ……………… Variable from 80Ω to 120Ω
Distance Accuracy ………….. +0.5 ft plus +0.01% of reading
……………………………………. +0.15 m plus +0.01% of reading


Maximum Range

Live Waveform ……………….. 63,700 ft (19,400 m) at 99.0% VOP
……………………………………. 38,600 ft (11,700 m) at 60.0% VOP
Range varies with VOP. Maximum testable cable length varies with
pulse width and cable type.

Input Protection
……… 400 VAC or VDC up to 60 Hertz
Velocity of Propagation Two user-selectable display formats.
VOP (%) ranging from 30.0% to 99.0%
Loaded Cable ………………… VOP (%) ranging from 0.8% to 20.0%
V/2 ranging from 45.0 to 148.4m/ms or 147.5 to 486.9 ft/ms
Loaded Cable ………………… V/2 ranging from 1.2 to 30.0 m/ms or
3.9 to 98.4 ft/ms
Waveform Storage
Standard ……………………….. 8 SUPER-STORE waveforms at 6144
samples each

Software Noise Filters
Standard ……………………….. 8x, 50/60 Hz

Resistance Fault Locator
Location Range ……………… 0 to 100 kft
Resistance Fault Range ……. 0 to 50M
Accuracy
3-Wire Test …………………….. +0.25% of DTS +0.4ohms
4-Wire Test …………………….. +0.25% of DTS +0.25ohms
Kupfmuller Test ……………… +1.0% of DTS +1 ohm

 

Noise/Balance Measurements

Longitudinal Balance ………. 40 to 62 dB
Frequency …………………….. 1004 Hz
Resolution …………………….. 1 dB
Accuracy ………………………. +2 dB
Noise Metallic ……………….. 0 to 50 dBrnC
Transverse Noise ……………. -90 to -40 dBmp
Resolution …………………….. 1 dB
Accuracy ………………………. +2 dB
Power Influence ……………. 40 to 100 dBrnC
Longitudinal Noise …………. -50 to 10 dBmp
Resolution …………………….. 1 dB
Accuracy ………………………. +2 dB

Multi-Meter
DC Voltage …………………….. 0 to 400V
Resolution …………………….. 0.1V
Accuracy ………………………. 1% +0.1V
AC Voltage …………………….. 0 to 400V
Resolution …………………….. 0.1V
Accuracy ………………………. 1% +0.1V
Foreign Battery ……………… 2 to 400V
Resolution …………………….. 0.1V
Accuracy ………………………. 1% +0.1V

Resistance

0 to 2 kΩ
Resolution …………………….. 0.1Ω
Accuracy ………………………. 0.2+0.2
2kΩ to 10kΩ
Resolution …………………….. 1
Accuracy ………………………. 0.2%+1¦

Insulation Resistance

0.00MΩ to 100MΩ
Resolution …………………….. 0.01M
Accuracy ………………………. +1%
Loop Current ………………… 0 to 120mA
Resolution …………………….. 0.1mA
Accuracy ………………………. 5% +0.1mA

Buying, Selling, Trading Riser Bond Model 6000